Instructions for use :
Refer to the instructions for more details
1. IDENTIFYING THE FACES ON THE PATCH
On a table, place the patch so that the back is facing you (control box against the table).
2. PREPARING THE ADHESIVE GEL REFILL
Open the sachet and take a refill of Gel adhesive. One refill corresponds to the right-hand side of the patch and the other to the left-hand side. Carefully remove the blue protection film, making sure that the adhesive gel stays in place on the transparent protection film.
If necessary, you can hold the gel in place with your finger. Keep the blue protective film to replace it on the patch after each use.
3. APPLYING THE GELS TO THE PATCH
Using the transparent protective film, position the Gel correctly on the patch, making sure that the tab of the Gel is superimposed on the tab of the patch. Proceed in the same way with the other gel, repeating steps 2 and 3. Once the two gels are positioned on the electrical circuits, remove the 2 transparent protective films, making sure that the gels remain on the patch (hold the gels with your finger if necessary).
1 pair of adhesive gels = approximately 30 uses
Note: you can throw away the transparent protective films
4. APPLYING AND USING THE PATCH
Apply the patch to the painful area and briefly press the ON/OFF button: 1 beep sounds and 1 green light comes on. You are in PROGRAMME 1. If you do not see a green light or hear a beep, the patch is completely discharged.
Recharge the patch using the cable supplied.
5. PROGRAMME SELECTION
This patch contains 3 programmes. Each programme lasts 30 minutes. For Plus details, refer to the full manual. By default, PROGRAMME 1 is selected automatically when the patch is switched on: this programme is recommended as the first line of defence. To change programme, press and hold the "+" button (approx. 3 seconds, until you hear a series of beeps): 2 beeps indicate that programme 2 has been selected. Release the button. Press and hold the button again to switch to programme 3: 3 beeps.
To start stimulation, go to the next step.
6. STARTING STIMULATION AND ADJUSTING INTENSITY
Once you have selected your programme, briefly press the "+" button once to start the stimulation.
Adjust the intensity by briefly pressing the '+' and '-' buttons
- .
If the sensation is painful, reduce the intensity.
there are 15 intensity levels available.
7. PATCH OFF
After 30 minutes, the device switches off automatically.
If you wish to switch off the device before the 30 minutes have elapsed, briefly press the ON/OFF button: 3 beeps and 3 light signals indicate that the device is switched off.
8. STORING THE PATCH
Before removing the patch, make sure it is switched off. Then gently remove the patch, making sure that the gels remain on the electrical circuit (hold the gels with your finger if necessary). Leave the gels in place on the patch and cover them with the retained blue protective films. Your patch is now ready for future use. For subsequent use, remove the blue protection films and go straight to step 4.
NOTE: when the patch no longer adheres sufficiently to the skin, you will need to moisten the gels to extend their life, as recommended in the instructions.